      摘要:
      针对塔河油田酸化油乳化程度高,常规方法无法实现深度脱水等现状,通过高频脉冲电脱水单因素和正交实验,对脱水过程中电压、频率、温度和脉宽比4个因素对脱水性能的影响进行研究。实验结果表明,高频脉冲电脱水的最佳参数为温度100℃,电压8 kV,频率4 kHz,脉宽比70%。
      Abstract:
      The acid crude from Tahe oil field is high emulsification, conventional methods could not achieve dehydration effectively. Factors for the performance by high frequency impulse electrostatic dehydration was investigated through one?factor at a time and orthogonal experiments. Effects of four factors such as temperature,voltage,frequency,duty cycle in the dehydration processing on dehydration performances were studied.Results indicated that the best conditions were the temperature of 100 ℃,the voltage of 8 kV,the frequency of 4 kHz,and the duty cycle of 70%.
      作者: 房维 韩萍芳
      Author: FANG Wei HAN Pingfang
      作者单位: 南京工业大学 生物与制药工程学院,江苏 南京,211800
      年,卷(期): 2017, 39(1)
      分类号: TE624.1
      在线出版日期: 2017年3月7日